1Mira Escape Thermostatic9.0, 9.8 kWThese instructions must be left with the userInstallation and User GuideFor SPARES, ADVICE or REPAIRSPlease call u
10Warning! Turn off the electrical and water supplies before proceeding with the installation of the Mira Escape. The electricity must be turned off a
11Three case inserts are supplied with the Mira Escape, so that they can be trimmed to suit the supplies entering the product. Before tting the cover
12Firmly connect the conductors. Do not exert strain on the terminal block.L = BROWNE = GREEN/YELLOWN = BLUERet the Service Tunnel and Cover. Ma
13Cold Water Supply Pipe (Bottom Entry)Service TunnelFixing ScrewHoles For CoverRetaining ScrewsCase InsertElectrical Supply CableTerminal BlockInlet
14COMMISSIONINGTurn control to full cold. Turn the water supply fully on.Check for water leaks. Set control to ‘I’. Switch on electrical supply.Press
15Turn control to full cold. The temperature will rise slightly.Set control to ‘II’._ + 0 - 10 Secs12.11.10.The temperature will rise further.Adjust
16_+COLD_+_+The warmer the shower, the lower the ow rate and vice versa.Heated water is produced by adjusting the ow of cold water passed through a
17The shower's top priority is to keep the desired water temperature constant. Electric showers with thermostatic control are able to keep a stab
18WARNING - THIS SHOWER CAN DELIVER SCALDING TEMPERATURES IF NOT OPERATED, INSTALLED OR MAINTAINED IN ACCORDANCE WITH THE INSTRUCTIONS,
19Using your ShowerRead the section “User Safety Information” rst.Note! At the end of every shower make sure that the shower head points into the cat
2Product Model Number ColourMira Escape 9.0 J95Hb/c Chrome, Satin/ChromeMira Escape 9.0 J95Hf WhiteMira Escape 9.8 J95G/H Chrome, Satin/ChromeMira Esc
20Water inlet pressure uctuations due to other draw offs (e.g. ushing toilet). Shower temperature will be controlled to within ± 2°C of the set temp
21FAULT DIAGNOSISThe trouble shooting information tabled below gives details on probable causes and remedies should difculties be encountered whilst
22Symptom Power LightLow Flow LightHeater Setting I / II / IIIProbable Cause Possible Remedy(continued)Unable to select a hot enough shower (cold only
23Symptom Power LightLow Flow LightHeater Setting I / II / IIIProbable Cause Possible RemedyOperation of temperature control has little or no effect
24USER MAINTENANCEUse your thumb or a soft cloth to wipe any limescale from the soft nozzlesThere are no user serviceable parts inside the shower.
25Cover Retaining ScrewCoverService TunnelMake sure that the electrical supply is turned off at the mains and that the water supply is fully turned of
26SPARE PARTSA416.38Inlet Clamp405.58Inlet Connector406.27Inlet FilterB, CB, C, DAA1563.719Thermal Switch1563.519Terminal Block1563.532 (9.0kW)1563.53
27ACCESSORIESGenuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guid
281060688-W2-L (1563) (J95G/H, J95Hf, J95Hb/c, J95Gc) © Kohler Mira Limited, October 2013Mira is a registered trade mark of Kohler Mira Limited.The co
3If you experience any difculty with the installation of your new shower, then please refer to “Fault Diagnosis”, before contacting Kohler Mira Limit
4 1 x Mira Escape 1 x Compression Nut 1 x Olive 3 x Case InsertsTick the appropriate boxes to familiarize yourself with the part names and to conrm t
5BROWNBROWNBROWNBLUEBLUEGREENGREENBROWNBROWNBROWNBLACKBLACKBLACKREDREDREDWIRING DIAGRAMThermal CutoutDual DiscTank ConnectionLoadInlet ConnectorPressu
6European Conformity InformationThe Mira Escape range of showers comply with the following European directives:2006/95/EC Low Voltage Directive, 2004/
7INSTALLATION REQUIREMENTSPlease read the Important Safety Information and specications sections at the front of this guide, and the requirements det
8Zone of Backow Risk30 mm MinimumToilet or Bidet FC5Hand Basin FC3Bath or Shower Tray FC3Electric Shower25 mm Minimum25 mm Minimum15. A full bore/no
9Double-poleIsolating SwitchConsumer UnitPlumbing and Electrical SchematicWARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:Electrical1.
Commentaires sur ces manuels